[FIX] hw_drivers: Start iot_devices thread after registering it
This commit was originally part of a larger commit related to an Ingenico double connection deadlock bugfix in V13, but in V14 most of the related code has moved to enterprise. When a driver thread is running, calling `disconnect` on it will delete it from iot_devices. If the driver thread gets added to iot_devices in the Interface thread after starting it, this means there is a tiny window of time where `disconnect` could be called and the thread wouldn't be in iot_devices yet, resulting in an exception. This change puts the driver thread in iot_devices before starting it, avoiding that scenario and the need to check in `disconnect` for that happening.
Diffstat (limited to 'addons')
-rw-r--r--addons/hw_drivers/interface.py6
1 files changed, 5 insertions, 1 deletions
diff --git a/addons/hw_drivers/interface.py b/addons/hw_drivers/interface.py
index 28ad1a55e0a..56952d1e084 100644
--- a/addons/hw_drivers/interface.py
+++ b/addons/hw_drivers/interface.py
@@ -51,8 +51,12 @@ class Interface(Thread, metaclass=InterfaceMetaClass):
_logger.info('Device %s is now connected', identifier)
d = driver(identifier, devices[identifier])
d.daemon = True
- d.start()
iot_devices[identifier] = d
+ # Start the thread after creating the iot_devices entry so the
+ # thread can assume the iot_devices entry will exist while it's
+ # running, at least until the `disconnect` above gets triggered
+ # when `removed` is not empty.
+ d.start()
break
def get_devices(self):